VCP CO2R-series - CO2 transmitter w/- Humidity & Temp options
 

We are experiencing some delays due to Covid-19 regulations. We thank you for your patience and will assist you as promptly as possible.

We are experiencing some delays due to Covid-19 regulations. We thank you for your patience and will assist you as promptly as possible.

Search
Menu Close

VCP CO2R-Series - CO2 Transmitter w/- Humidity & Temp options

The CO2R-series can measure Carbon Dioxide (Co2) ranges of 400-2.000 ppm, 0-2.000 ppm, 0-5.000 ppm, 0-10.000 ppm
Part Number: CO2R-Series
Manufacturer:
0Types Available
Back to Previous Page
Product Files

Carbon Dioxide (CO2) transmitter CO2R-series have a maintenance-free NDIR sensor

Measuring ranges for Carbon Dioxide (CO2) are 400-2.000 ppm, 0-2.000 ppm, 0-5.000 ppm, 0-10.000 ppm selectable ranges with DIP switch. On request 0-1.000 ppm.

0-10 Vdc, 2-10 Vdc, 4-20 ma, 0-5 Vdc or 1-5 Vdc (One output and Two CO2 outputs available).

The estimated operating life for Carbon Dioxide (CO2) transmitter is approx. 15 years.

Featuring ABC functionality – Automatic Baseline Calculation.

Accuracy is 70 ppm +3 % reading.

Power supply 24 Vac/dc.


Options

  • Modbus RS485
  • LCD Display
  • 1 x relay output, can be set individually
  • 2 x relay outputs, can be set individually
  • Buzzer

 

Temperature and Humidity Options

  • Temperature measuring ranges 0 to +50°C or -30 to +70°C
  • Temperature output 0-10 Vdc, 2-10 Vdc, 4-20 mA, 0-5 Vdc or 1-5 Vdc
  • Humidity measuring ranges 0 to 100% rH
  • Humidity output 0-10 Vdc, 2-10 Vdc, 4-20 mA, 0-5 Vdc or 1-5 Vdc

 

Ordering examples

CO2R 51 M

  • Carbon Dioxide (CO2) room transmitter
  • Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
  • Modbus RS485 communication

CO2R 51 MDR2B

  • Carbon Dioxide (CO2) room transmitter
  • Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
  • Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer

CO2R C1T1H1 MDR2B

  • Carbon Dioxide (CO2) room transmitter with Temperature and Humidity options
  • CO2 output 0-10 Vdc
  • TEMP. output 0-10 Vdc
  • HUM. output 0-10 Vdc
  • Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer


See the datasheet for more information.

Carbon Dioxide (CO2) transmitter CO2R-series have a maintenance-free NDIR sensor

Measuring ranges for Carbon Dioxide (CO2) are 400-2.000 ppm, 0-2.000 ppm, 0-5.000 ppm, 0-10.000 ppm selectable ranges with DIP switch. On request 0-1.000 ppm.

0-10 Vdc, 2-10 Vdc, 4-20 ma, 0-5 Vdc or 1-5 Vdc (One output and Two CO2 outputs available).

The estimated operating life for Carbon Dioxide (CO2) transmitter is approx. 15 years.

Featuring ABC functionality – Automatic Baseline Calculation.

Accuracy is 70 ppm +3 % reading.

Power supply 24 Vac/dc.


Options

  • Modbus RS485
  • LCD Display
  • 1 x relay output, can be set individually
  • 2 x relay outputs, can be set individually
  • Buzzer

 

Temperature and Humidity Options

  • Temperature measuring ranges 0 to +50°C or -30 to +70°C
  • Temperature output 0-10 Vdc, 2-10 Vdc, 4-20 mA, 0-5 Vdc or 1-5 Vdc
  • Humidity measuring ranges 0 to 100% rH
  • Humidity output 0-10 Vdc, 2-10 Vdc, 4-20 mA, 0-5 Vdc or 1-5 Vdc

 

Ordering examples

CO2R 51 M

  • Carbon Dioxide (CO2) room transmitter
  • Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
  • Modbus RS485 communication

CO2R 51 MDR2B

  • Carbon Dioxide (CO2) room transmitter
  • Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
  • Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer

CO2R C1T1H1 MDR2B

  • Carbon Dioxide (CO2) room transmitter with Temperature and Humidity options
  • CO2 output 0-10 Vdc
  • TEMP. output 0-10 Vdc
  • HUM. output 0-10 Vdc
  • Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer


See the datasheet for more information.

Picture of Carbon Dioxide (CO2) transmitter for room mounting
Carbon Dioxide (CO2) transmitter for room mounting
Carbon Dioxide (CO2) transmitter for room mounting, IP41Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 VdcModbus RS485 communication
Part Number: CO2R 51 M
$357.00 ex GST
i h
Delivery date: 4-5 weeks
Picture of Carbon Dioxide (CO2) transmitter for room mounting (2 x Relay)
Carbon Dioxide (CO2) transmitter for room mounting (2 x Relay)
Carbon Dioxide (CO2) transmitter for room mounting, IP41Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 VdcModbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer
Part Number: CO2R 51 MDR2B
$437.00 ex GST
i h
Delivery date: 4-5 weeks
Picture of Carbon Dioxide (CO2) transmitter for room mounting w/- Temperature and Humidity options
Carbon Dioxide (CO2) transmitter for room mounting w/- Temperature and Humidity options
Carbon Dioxide (CO2) transmitter for room mounting, IP41, with Temperature and Humidity options,CO2 output 0-10 VdcTEMP. output 0-10 VdcHUM. output 0-10 VdcModbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer
Part Number: CO2R C1T1H1 MDR2B
$494.00 ex GST
i h
Delivery date: 4-5 weeks