See how real-time data transforms wetland conservation. Read the use case now!

  • Home
  • About Us
  • Resource Centre
  • News
1300 186 107
HOBO Data Loggers
  • Products
    • By Measurement
      • CO2
      • Temperature
      • Water Temperature
      • Water Level
      • Soil Moisture
      • Shop All
    • By Product Type
      • Data Loggers
      • Sensors
      • Kits & Systems
      • Software
      • Accessories
      • Shop All
    • By Environment
      • Climate Controlled
      • Indoor
      • Outdoor
      • Underwater
      • Shop All
    • Take your monitoring to the next level with HOBO's MX800 Multiparameter Water Quality Data Loggers
  • Applications
    • Building Performance
      • Air Quality
      • Energy/Power
      • Warehousing
    • Field Monitoring & Research
      • HOBOnet Wireless Networks
      • Soil Health
    • Water
      • Water Quality
      • Water Level
      • Water Temperature
      • Wetlands Monitoring
    • Outdoor
      • Agriculture
      • Irrigation
      • Weather
    • Pharmaceuticals
      • Fridge/Freezer Monitoring
      • Shipment & Storage Monitoring
  • Support
    • Resource Centre
      • Quick Start Guides
      • User Manuals
      • Datasheets
      • Webinars
      • Videos
    • Whitepaper Featured
      • Choosing a Water Level Logger: 5 Things you Should Know
    • Webinar Featured
      • HOBO Water Monitoring Platform for the Future Webinar
    • How-To Video Featured
      • Choosing a Remote Field Monitoring System – Factors to Consider
  • Home
  • About Us
  • Resource Centre
  • News
HOBO Data Loggers
  • Products
    • By Measurement
      • CO2
      • Temperature
      • Water Temperature
      • Water Level
      • Soil Moisture
      • Shop All
    • By Product Type
      • Data Loggers
      • Sensors
      • Kits & Systems
      • Software
      • Accessories
      • Shop All
    • By Environment
      • Climate Controlled
      • Indoor
      • Outdoor
      • Underwater
      • Shop All
    • Take your monitoring to the next level with HOBO's MX800 Multiparameter Water Quality Data Loggers
  • Applications
    • Building Performance
      • Air Quality
      • Energy/Power
      • Warehousing
    • Field Monitoring & Research
      • HOBOnet Wireless Networks
      • Soil Health
    • Water
      • Water Quality
      • Water Level
      • Water Temperature
      • Wetlands Monitoring
    • Outdoor
      • Agriculture
      • Irrigation
      • Weather
    • Pharmaceuticals
      • Fridge/Freezer Monitoring
      • Shipment & Storage Monitoring
  • Support
    • Resource Centre
      • Quick Start Guides
      • User Manuals
      • Datasheets
      • Webinars
      • Videos
    • Whitepaper Featured
      • Choosing a Water Level Logger: 5 Things you Should Know
    • Webinar Featured
      • HOBO Water Monitoring Platform for the Future Webinar
    • How-To Video Featured
      • Choosing a Remote Field Monitoring System – Factors to Consider
    • My account
    • Quote
    • Cart
←
→
  • OVERVIEW

    Used to measure sunlight under a plant canopy where the light field is non-uniform, the LI-191R Line Quantum Sensor measures PAR with a single detector integrating measurements over its 1-meter length. The LI-191R makes it easy to measure under-canopy light in many plots quickly and consistently. It measures light in units of Photosynthetic Photon Flux Density (PPFD), which is expressed as μmol s-1 m-2.

    Why choose the LI-191R PAR Light Sensor?

    • Improved water resistance for long-term outdoor deployment
    • Integrated measurements using a single detector prevents variance found in sensors that use multiple detectors
    • Selected by the National Ecological Observatory Network (NEON®) for integrated PAR measurements
    • Compatible with the HOBOnet Analog Mote that transmits data automatically to cellular RX stations and LI-COR Cloud remote monitoring platform.

     

  • SPECIFICATIONS

     

    Absolute Calibration ± 10% traceable to National Institute of Science and Technology (NIST). The LI-191 is calibrated via transfer calibration using a reference LI-190R Quantum Sensor. Transfer error is ± 5% (included in the ± 10%)
    Sensitivity Typically 7 μA per 1,000 μmol s-1 m-2
    Linearity Maximum deviation of 1% up to 10,000 μmol s-1 m-2
    Response Time 10 μs
    Temperature Dependence ± 0.15% per °C maximum
    Cosine Correction Acrylic diffuser
    Azimuth < ± 2% error over 360° at 45° elevation
    Operating Temperature Range −40 °C to 65 °C
    Relative Humidity Range 0% to 95% RH, Non-Condensing
    Sensitivity Variation over Length ± 7% maximum using a 2.54 cm (1”) wide beam from an incandescent light source.
    Sensing Area 1 m × 12.7 mm (39.4” × 0.50”)
    Detector High stability silicon photovoltaic detector (blue enhanced)
    Sensor Housing Weatherproof anodized aluminum housing with acrylic diffuser and stainless steel hardware.
    Size (L x W x D) 121.3 × 2.54 × 2.54 cm (47.7” × 1.0” × 1.0”)
    Weight 1.4 kg (3.0 lbs.)
    Cable Length 3.1m (10.0 ft.)

     

  • HOW DOES IT WORK?

    How does the line quantum sensor work?

    The LI-191R uses a 1-meter long quartz rod under a diffuser to direct light to a single filtered silicon photodiode. The entire LI-191R diffuser is sensitive to light over its 1-meter length. Since the diffuser is one continuous piece, the LI-191R essentially integrates an infinite number of points over its surface into a single value that represents light from the entire 1-meter length. Optical filters block radiation with wavelengths beyond 700 nm, which is critical for under-canopy measurements, where the ratio of infrared to visible light may be high. The unique design of the LI-191R provides an excellent quantum response that is close to the ideal quantum response.

     

    Learn More About the Science Behind the Design
/ Shop / Products / LI-COR / LI-COR LI-191R - Line Quantum Sensor

LI-COR LI-191R – Line Quantum Sensor

The LI-191R Line Quantum Sensor integrates below-canopy photosynthetically active radiation measurements over a 1-meter length in units of Photosynthetic Photon Flux Density (PPFD). Millivolt output.

Important Information

This sensor requires a Millivolt adapter and HOBOnet Analog Mote for connection to the RX3000 remote monitoring station.

Part Number: LI-191R
Delivery Timeframe: 6+ weeks
Category: Products
Add to quote loading
Call for pricing

Product Resources

←
→

Light Measurement Brochure

Operating Instructions

Application Notes, Tech Tips, and Other Documents

Troubleshooting

Video Library

Frequently Asked Questions

You May Also Like

←
→

LI-COR LI-190R - Quantum Sensor

$1,214.00 – $1,557.00 ex GST

VIEW PRODUCT

HOBOnet Analog Input Mote

$1,149.00 ex GST

VIEW PRODUCT

Fast Delivery: Free for orders over $100

Secure Online Payments: Visa or Mastercard

Quick Links

  • Products
  • Resource Centre
  • About HOBO Data Loggers
  • My Account
  • Contact Us

HEAD OFFICE

1300 186 107
[email protected]

Sydney  |  Melbourne  |  Brisbane  |  Perth  |  Adelaide

Quality & Security Guaranteed

  • Shipping & Returns
  • Terms and Conditions
  • Privacy Policy

Copyright © 2025 OneTemp. All rights reserved.