Onset Hobo Data Loggers Authorised Distributor

Air Velocity Sensor - T-DCI-F900-S-O - 0 - 5 m/s, 1 Piece Body

The F900 S-O Airflow Sensor is designed to measure the velocity of airflows in applications such as HVAC, industrial processes, automotive, air filtration systems, electronics enclosures and critical containment areas.
Part Number: T-DCI-F900-S-O
$731.00 ex GST
[$804.10 inc GST]
Product Files

The F900 S-O Airflow Sensor is designed to measure the velocity of airflows in applications such as HVAC, industrial processes, automotive, air filtration systems, electronics enclosures and critical containment areas.

Requires analog port selection during RX3000 and U30 system configuration and use of a S-FS-CVIA when using the H22-001 logger. When using a U12 logger, this sensor requires an 0-5 Vdc analog input cable (CABLE-ADAP5) and external power provided by an AC adapter (AC-SENS-1).

  • This adds the ability for users to be able to measure air velocity (in ducts, e.g.) from which CFM can be computed.

Environment:
The T-DCI-F900-S-O Sensor is for use in Indoor environments

Measurements:
The T-DCI-F900-S-O Sensor supports the following measurements :

Air Velocity

The F900 S-O Airflow Sensor is designed to measure the velocity of airflows in applications such as HVAC, industrial processes, automotive, air filtration systems, electronics enclosures and critical containment areas.

Requires analog port selection during RX3000 and U30 system configuration and use of a S-FS-CVIA when using the H22-001 logger. When using a U12 logger, this sensor requires an 0-5 Vdc analog input cable (CABLE-ADAP5) and external power provided by an AC adapter (AC-SENS-1).

  • This adds the ability for users to be able to measure air velocity (in ducts, e.g.) from which CFM can be computed.

Environment:
The T-DCI-F900-S-O Sensor is for use in Indoor environments

Measurements:
The T-DCI-F900-S-O Sensor supports the following measurements :

Air Velocity

Measurement ranges, "O" model: 0.15 - 5 m/s (30 - 985 fpm)

Measurement range, "P" model: 0.15 - 10 m/s (30 - 1969 fpm)

Accuracy: Greater of 10% of reading or +/-0.05 m/s or 1% full-scale

Standard medium: Air at standard pressure (101.3 kPa, 29.95" Hg)

Operating temperature range: 15 – 35 C (59 – 95 F)

Storage temperature: -10 to 100C

Supply voltage: 7-13 VDC

Supply current: 40 - 75 mA (10K ohm nominal)

Warm-up time: < 5 sec 

Response time: 1.5 sec

Output:
 Linear 0 - 4 VDC full scale for calibrated range, up to 4.9 VDC beyond calibrated range

Sensor head material: Plastic

Dimensions: 100 mm x 12 mm diameter for "S" model, 91 mm x 12 mm for "L" model

Weight: "S" model 1 oz., "L" model 1.8 oz.

Vibration: Up to 25 G

Acceptable angle: +/- 300 from perpendicular

Repeatability: +/- 1% under same conditions

Online store by DBG Technologies, powered by LiveCube