Split-core AC Current Sensor - CTV

A split-core AC current sensor with models over the range of 0 to 600 amps AC for use with HOBO UX120-006, U12 and ZW data loggers with external input channels.
Part Number: CTV-A, CTV-B, CTV-C, CTV-D, CTV-E
*
$221.00 ex GST
[$243.10 inc GST]
Product Files

A split-core AC current sensor responsive over the range of 0 to 600 amps AC in 5 Models. For use with UX120-006, U12 and ZW data loggers with external input channels. With an input current of AC current, sine wave, single phase 50 Hz or 60 Hz, load power factor 0.5 to 1.0 lead or lag. 

Features:

  • UL listed
  • Sensor power induced from line voltage
  • Self-gripping split-core design for fast installation
Environment:
The CTV-C Sensor is for use in Indoor environments
Measurements:
The CTV series Sensor supports the following measurements : AC Current

A split-core AC current sensor responsive over the range of 0 to 600 amps AC in 5 Models. For use with UX120-006, U12 and ZW data loggers with external input channels. With an input current of AC current, sine wave, single phase 50 Hz or 60 Hz, load power factor 0.5 to 1.0 lead or lag. 

Features:

  • UL listed
  • Sensor power induced from line voltage
  • Self-gripping split-core design for fast installation
Environment:
The CTV-C Sensor is for use in Indoor environments
Measurements:
The CTV series Sensor supports the following measurements : AC Current

Ranges available (AC Amps): 0-20, 0-50, 0-100, 0-200, 0-600

Accuracy with H8: ±5.0% of full scale
Accuracy with U12: ±4.5% of full scale
Accuracy with UX120-006M: ±2.1% of full scale
Response time (from 10% to 90% of amplitude): see table
Input current: AC current, sine wave, single phase 50 Hz or 60 Hz, load power factor 0.5 to 1.0 lead or lag
Voltage rating: 600 VAC
Construction and operating environment: Molded plastic housing for indoor use per UL508; pivoting leg (leg on CTV-D and CTV-E units is fully removable); UL listed.
Cable Length: 1.8m cable (6 foot)
Dimensions: see table 
Notes:
  1. AC current sensors are not designed for use with Intrinsically Safe (IS) loggers
Part No.Range (Amps AC)Approximate Response Time (milliseconds)Dimensions
WindowOuter LengthOuter WidthHeight
CTV-A 0–20 440 2.8 cm x 2.3 cm 1.1 in. x 0.9 in. 7.4 cm 2.9 in 6.6 cm 2.6 in 2.5 cm 1.0 in
CTV-B 0–50 200 2.8 cm x 2.3 cm 1.1 in. x 0.9 in 7.4 cm 2.9 in 6.6 cm 2.6 in 2.5 cm 1.0 in
CTV-C 0–100 100 2.8 cm x 2.3 cm 1.1 in. x 0.9 in 7.4 cm 2.9 in 6.6 cm 2.6 in 2.5 cm 1.0 in
CTV-D 0–200 450 3.8 cm x 3.3 cm 1.5 in. x 1.3 in 9.9 cm 3.9 in 11.9 cm 4.7 in 2.8 cm 1.1 in
CTV-E 0–600 490 7.4 cm x 6.4 cm 2.9 in. x 2.5 in 13.5 cm 5.3 in 15.0 cm 5.9 in 2.8 cm 1.1 in