Onset Hobo Data Loggers Authorised Distributor

E50B2 Power & Energy Meter - T-VER-E50B2

The E50B2 Power & Energy Meter combines exceptional performance and easy installation to deliver a cost-effective solution for power and energy monitoring needs. It works with the HOBO UX, U30, ZW, H22 & H21 data loggers.
Part Number: T-VER-E50B2
$1,450.00 ex GST
[$1,595.00 inc GST]

The E50B2 Power & Energy Meter combines exceptional performance and easy installation to deliver a cost-effective solution for power and energy monitoring needs. The T-VER-E50B2 can be installed on standard DIN rail or surface mounted as needed. It works with the HOBO UX, U30, ZW, H22 & H21 data loggers.

  • Measures Power Factor (PF), Reactive Power (VAR), Watt Hours (Wh) and more.
  • Range: 90-600VAC – Wye or Delta configurations
  • Accuracy: ANSI 12.20 0.5% accuracy, IEC 62053-22 Class 0.5S
  • Compatible with CTs from 5 to 32000A (333mV output)
  • Bright backlit LCD
  • UL listed, CE, California CSI Solar, ANSI C12.20

Environment:
The T-VER-E50B2 Sensor is for use in Indoor environments

Measurements:
The T-VER-E50B2 Sensor supports the following measurements :

AC Current, AC Voltage, Amp Hour (Ah), Amps (A), Kilowatt Hours (kWh), Kilowatts (kW) , Power Factor (PF), Volt-Amp Reactive (VAR), Volt-Amp Reactive Hour (VARh), Volt-Amps (VA), Volts (V), Watt Hours (Wh), Watts (W)

The E50B2 Power & Energy Meter combines exceptional performance and easy installation to deliver a cost-effective solution for power and energy monitoring needs. The T-VER-E50B2 can be installed on standard DIN rail or surface mounted as needed. It works with the HOBO UX, U30, ZW, H22 & H21 data loggers.

  • Measures Power Factor (PF), Reactive Power (VAR), Watt Hours (Wh) and more.
  • Range: 90-600VAC – Wye or Delta configurations
  • Accuracy: ANSI 12.20 0.5% accuracy, IEC 62053-22 Class 0.5S
  • Compatible with CTs from 5 to 32000A (333mV output)
  • Bright backlit LCD
  • UL listed, CE, California CSI Solar, ANSI C12.20

Environment:
The T-VER-E50B2 Sensor is for use in Indoor environments

Measurements:
The T-VER-E50B2 Sensor supports the following measurements :

AC Current, AC Voltage, Amp Hour (Ah), Amps (A), Kilowatt Hours (kWh), Kilowatts (kW) , Power Factor (PF), Volt-Amp Reactive (VAR), Volt-Amp Reactive Hour (VARh), Volt-Amps (VA), Volts (V), Watt Hours (Wh), Watts (W)
Measurement Accuracy:  
   Real Power and Energy IEC 62053-22 Class 0.5S, ANSI C12.20 0.5%
   Reactive Power and Energy IEC 62053-23 Class 2, 2%
   Current 0.4% (+0.015% per °C deviation from 25°C) from 5% to 100% of range;
0.8% (+0.015% per °C deviation from 25°C) from 1% to 5% of range
   Voltage 0.4% (+0.015% per °C deviation from 25°C) from 90V (L-N) to 600VAC (LL)
   Sample Rate 2520 samples per second
   Data Update Rate 1 sec
   Type of Measurements True RMS up to the 21st harmonic 60 Hz, One to three phase AC system
Input Voltage Characteristics:  
   Measured AC Voltage Minimum 90VL-N (156VL-L) for stated accuracy
UL Maximums: 600VL-L (347VL-N)
CE Maximums: 300VL-N (520V L-L)
   Metering Over Range +20%
   Impedance 2.5 MΩ (L-N)/5 MΩ (L-L)
   Frequency Range 45 to 65 Hz
Input Current Characteristics:  
   CT Scaling Primary: Adjustable from 5 A to 32,000 A
   Measurement Input Range 0 to 0.333VAC or 0 to 1.0VAC (+20% over-range)
   Impedance 10.6kΩ (1/3 V mode) or 32.1kΩ (1 V mode)
Output:  
   Alarm Contacts N.C., static output (30VAC/DC, 100mA max. @ 25°C, derate 0.56mA per °C above 25°C)
   Real/Reactive Energy
    Pulse Contacts
N.O., static output (30VAC/DC, 100mA max. @ 25°C,
derate 0.56mA per °C above 25°C)
Mechanical Characteristics:  
   Weight 0.62 lb (0.28 kg)
   IP Degree of Protection (IEC 60529) IP40 front display; IP20 Meter
   Display Characteristics Back-lit blue LCD
   Terminal Block Screw Torque 0.37 ft•lb (0.5 N•m) nominal/0.44 ft-lb (0.6 N•m) max
   Terminal Block Wire Size 26 to 14 AWG (0.13 to 2.08 mm2)
   Rail T35 (35mm) DIN Rail per EN50022
Environmental Conditions:  
   Operating Temperature Meter: -30° to 70°C; Display: 0° to 50°C
   Storage Temperature Meter: -40° to 85°C; Display: -10° to 60°C
   Humidity Range <95% RH (non-condensing)
   Altitude of Operation 3 km max.
Metering Category:  
   North America CAT III; for distribution systems up to 347 V L-N/600VAC L-L
   CE CAT III; for distribution systems up to 300 V L-N
   Dielectric Withstand Per UL 508, EN61010
   Conducted and Radiated Emissions FCC part 15 Class B, EN55011/EN61000 Class B (residential and light industrial)
   Conducted and Radiated Immunity EN61000 Class A (heavy industrial)
Safety:  
   North America (cULus) UL508 (open type device)/CSA 22.2 No. 14-05
   Europe (CE) EN61010-1:2001