Onset Hobo Data Loggers Authorised Distributor

CTS Series Split-Core Current Transformers - T-MAG-SCT - for Loggers

The CTS series CTs are available with windows from 0.75 inch up to 2.0 inch. They have a removable section, so that they can be installed without interrupting the circuit.
Part Number: CTS
*
$125.00 ex GST
[$137.50 inc GST]

The CTS series CTs are available with windows from 0.75 inch up to 2.0 inch. They have a removable section, so that they can be installed without interrupting the circuit.

  • 0.333 Vac output at rated current
  • Accuracy ±1% from 10% to 100% of rated current
  • Phase angle <2° degrees at 50% of rated current (valid for 70 A or higher)
  • 8 ft. twisted-pair wire, 600 Vac rated
  • UL recognized for voltages up to 600 Vac, CE mark, RoHS
  • No exposed metal
  • Qualified under the Buy American provision in the American Recovery and Reinvestment Act of 2009 (ARRA).
  • Dimensional drawing
Onset Part numbers T-MAG-SCT-xxx
 
ModelI.D.Rated Amps (yyy)Max. AmpsMax. Wire Gauge
CTS-0750-yyy 0.75" 5, 15, 30, 50, 70, 100, 150, 200 200 3/0, 300* kcmil
CTS-1250-yyy 1.25" 70, 100, 150, 200, 250, 300, 400, 600 800 500 kcmil, 750* kcmil
CTS-2000-yyy 2.00" 400, 600, 800, 1000, 1200, 1500 2000 750 kcmil
 
The CT suffix "-yyy" is the rated amps. The "I.D." is the inside diameter of the CT. The "Max. Amps" is the highest continuous current that the CT can handle without being damaged.
The "Max Wire Gauge" is the largest wire gauge that should fit through this size of CT.
Note: CTS-0750 Series CTs with a current rating less then 70A do not meet the published phase angle accuracy specifications. For applications where accuracy is important, we recommend using the CTT Series solid core CTs, the CTM Series or ACT Series split-core CTs instead.
* These sizes may or may not fit, depending on the insulation thickness.
Model List: CTS-0750-005, CTS-0750-015, CTS-0750-030, CTS-0750-050, CTS-0750-070, CTS-0750-100, CTS-0750-150, CTS-1250-070, CTS-1250-100, CTS-1250-150, CTS-1250-200, CTS-1250-250, CTS-1250-300, CTS-1250-400, CTS-1250-600, CTS-2000-400, CTS-2000-600, CTS-2000-800, CTS-2000-1000, CTS-2000-1200, CTS-2000-1500

Safety Note

Warning: Hazardous Voltages - Only qualified personnel or licensed electricians should install the WattNode meter and current transformers.

Note: we stock a selection of these models, others are imported on request.

The CTS series CTs are available with windows from 0.75 inch up to 2.0 inch. They have a removable section, so that they can be installed without interrupting the circuit.

  • 0.333 Vac output at rated current
  • Accuracy ±1% from 10% to 100% of rated current
  • Phase angle <2° degrees at 50% of rated current (valid for 70 A or higher)
  • 8 ft. twisted-pair wire, 600 Vac rated
  • UL recognized for voltages up to 600 Vac, CE mark, RoHS
  • No exposed metal
  • Qualified under the Buy American provision in the American Recovery and Reinvestment Act of 2009 (ARRA).
  • Dimensional drawing
Onset Part numbers T-MAG-SCT-xxx
 
ModelI.D.Rated Amps (yyy)Max. AmpsMax. Wire Gauge
CTS-0750-yyy 0.75" 5, 15, 30, 50, 70, 100, 150, 200 200 3/0, 300* kcmil
CTS-1250-yyy 1.25" 70, 100, 150, 200, 250, 300, 400, 600 800 500 kcmil, 750* kcmil
CTS-2000-yyy 2.00" 400, 600, 800, 1000, 1200, 1500 2000 750 kcmil
 
The CT suffix "-yyy" is the rated amps. The "I.D." is the inside diameter of the CT. The "Max. Amps" is the highest continuous current that the CT can handle without being damaged.
The "Max Wire Gauge" is the largest wire gauge that should fit through this size of CT.
Note: CTS-0750 Series CTs with a current rating less then 70A do not meet the published phase angle accuracy specifications. For applications where accuracy is important, we recommend using the CTT Series solid core CTs, the CTM Series or ACT Series split-core CTs instead.
* These sizes may or may not fit, depending on the insulation thickness.
Model List: CTS-0750-005, CTS-0750-015, CTS-0750-030, CTS-0750-050, CTS-0750-070, CTS-0750-100, CTS-0750-150, CTS-1250-070, CTS-1250-100, CTS-1250-150, CTS-1250-200, CTS-1250-250, CTS-1250-300, CTS-1250-400, CTS-1250-600, CTS-2000-400, CTS-2000-600, CTS-2000-800, CTS-2000-1000, CTS-2000-1200, CTS-2000-1500

Safety Note

Warning: Hazardous Voltages - Only qualified personnel or licensed electricians should install the WattNode meter and current transformers.

Note: we stock a selection of these models, others are imported on request.

Online store by DBG Technologies, powered by LiveCube